V29 Differentiation of treatment-related changes from high-grade glioma progression: A direct comparison between FET PET and ADC values obtained by DWI MRI J. Werner1, G. Stoffels2, T. Lichtenstein3, J. Borggrefe3, G. Ceccon1, N. J. Shah2, G. R. Fink1, K. J. Langen2, C. Kabbasch3, N. Galldiks1 1University Hospital Cologne, Dept. of Neurology, Cologne; 2Research Center Jülich, Inst. of Neuroscience and Medicine (INM-4), Jülich; 3University Hospital Cologne, Dept. of Neuroradiology, Cologne | |
Ziel/Aim: Following brain cancer treatment, the capacity of anatomical MRI to differentiate neoplastic tissue from treatment-related changes such as pseudoprogression is limited. The aim of this study was to compare apparent diffusion coefficient (ADC) values obtained by diffusion-weighted MRI (DWI) with static parameters of O-(2-[18F]fluoroethyl)-L-tyrosine (FET) PET for the differentiation of treatment-related changes from tumor progression.Methodik/Methods: Forty-eight pretreated high-grade glioma patients (mean age, 50±15 years) with anatomical MRI findings suspicious for tumor progression (median time after completion of last treatment, 16 weeks) were additionally investigated using DWI MRI and FET PET. Maximum and mean tumor-to-brain ratios (TBRmax/mean) of FET uptake were determined (20-40 minutes post-injection). Regions-of-Interest analyses were performed concerning the enhancing lesion on ADC maps calculated from DWI MRI. Diagnoses were confirmed neuropathologically (21%; 10 patients) or clinico-radiologically (79%; 38 patients). Diagnostic performances of TBRs and ADC values for the correct differentiation were evaluated each alone using receiver-operating-characteristic analyses, or the Fisher Exact test for a combinational approach.Ergebnisse/Results: Ten of 48 patients had treatment-related changes (21%). The diagnostic performance of FET PET was clearly higher (threshold TBRmean, 1.95; sensitivity, 100%; specificity, 79%; accuracy, 83%; AUC 0.89±0.05; P-3 mm2/s; sensitivity, 60%; specificity; 79%; accuracy, 75%; AUC 0.73±0.09; P=0.05). The combination of both imaging parameters did not increase the accuracy (64%; P=0.144).Schlussfolgerungen/Conclusions: Static FET PET seems to add valuable clinical information regarding the differentiation of early treatment-related changes from tumor progression and outperforms ADC values for this highly relevant clinical question. |